Electrical panel glossary and FAQ

This glossary explains the terms that appear in electrical panel specifications, tenders and quotations, in plain English. It covers switchgear devices such as ACBs, MCCBs and VCBs, panel types such as PCC, MCC, APFC and AMF, and specification terms such as fault level, Form 4, IP rating and kVAR.

By Kulaina engineering team ·

Switchgear devices

ACB (air circuit breaker): a large breaker, usually the incomer of an LT panel, that interrupts high fault currents in air.

MCCB (moulded case circuit breaker): a breaker for medium currents, used for outgoing feeders.

MCB (miniature circuit breaker): a small breaker for individual lighting and power circuits in distribution boards.

VCB (vacuum circuit breaker): the usual breaker in HT panels, which interrupts the arc inside a vacuum.

Panel types

PCC (power control centre): the main LT panel that distributes incoming power to feeders and sub-panels.

MCC (motor control centre): a panel of motor starters, drives and protection.

APFC (automatic power factor correction): a panel that switches capacitor stages to keep power factor near unity.

AMF (auto mains failure): a panel that starts the DG set and transfers the load when the supply fails.

ACDB (AC distribution box): in a solar plant, the box that combines and protects inverter outputs.

Specification terms

Fault level: the current that would flow in a short circuit at that point, in kA. Every device at that point must withstand it, and every breaker must be able to interrupt it. HT fault levels are often given in MVA.

Form 4: a construction that separates busbars, functional units and terminals, so one feeder can be worked on while the rest stays live.

IP rating: protection against dust and water, such as IP54. The first digit is protection against solid objects, from fingers to dust; the second is water.

kVAR: the unit of reactive power. APFC panels are rated in kVAR.

Power factor: the ratio of useful power (kW) to apparent power (kVA). Electricity boards penalise low power factor.

Detuned reactor: a reactor in series with capacitors that protects them from harmonics.

DOL and star-delta: two ways of starting a motor. DOL connects it straight to the supply; star-delta reduces the starting current.

VFD (variable frequency drive): controls a motor’s speed by varying the supply frequency.

TPN and SPN: triple pole and neutral, or single pole and neutral. A TPN board takes a three-phase, four-wire supply; an SPN board takes one phase and neutral.

SLD (single-line diagram): a drawing of the electrical system with each circuit shown as one line.

BOQ (bill of quantities): the itemised list of equipment in a tender.

Related products

Frequently asked questions

What should a panel enquiry include?

A single-line diagram or load list, the incoming supply and fault level, the panel type, any tender specification or BOQ, and where the panel will be installed. Missing details can be worked out in a site study.

What is the difference between HT and LT?

HT, or high tension, is the high-voltage supply from the utility, before the transformer. LT, or low tension, is the 415 V or 230 V supply after the transformer that feeds equipment.